Schneider ABLS1A24050 - POWER SUPPLY 24V 5A 1PH OPTIMIZED
Schneider

ABLS1A24050 - POWER SUPPLY 24V 5A 1PH OPTIMIZED

Schneider ABLS1A24050, POWER SUPPLY 24V 5A 1PH OPTIMIZED. Category: Power supplies for industrial use, rail mounting. Request a quote for price and lead time.

Key Specifications

Range Of Product
Modicon Power Supply
Product Or Component Type
Power supply
Power Supply Type
Regulated switch mode
Variant Option
Optimized

Product Description

This ABLS regulated switch mode power supply (SMPS) supplies direct current voltage. It has a rated input of 100V to 240V AC and 140 V to 340 V DC, a rated output current of 5A at 24V DC and a rated power output of 120W. It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water. It installs on omega rail or fixing by screw. Its width is 40mm, its height is 123,6mm, its depth is 117,6mm. It ensures a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected. It weighs 0.550kg. It is a power supply for industrial use, rail mounting. It conforms to EN62368-1, ENIEC61010-1/2-201, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/-1-201, CSAC22.2No62368-1/No61010-2-201/No61010-1 standards, and certified by CE, CUL listed/recognized, RCM, CBscheme. The Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection. The type of protection is 13A, C-Curve. It has in the front face a LED indicating presence of DC output voltage, and a QR code for access to the latest technical documentation. Thanks to its book housing, it can be installed either in enclosures or industrial panels by clipping on omega (DIN) rail. It brings energy to your automated systems. Designed for simple machines and applications, modular power supplies are primarily appreciated for their extreme compactness.

Key Features

  • "One of the most compact on the market"
  • "Up to +70°C ambiant temperature"
  • "6 output terminals"
  • "Conformal coating in order to resist to common dust and chemical pollutants"
  • "High degree of output voltage stability"

Technical Specifications

Main9
Range Of ProductModicon Power Supply
Product Or Component TypePower supply
Power Supply TypeRegulated switch mode
Variant OptionOptimized
Enclosure MaterialAluminium
Nominal Input Voltage100...240 V AC single phase; 100...240 V AC phase to phase; 140...340 V DC
Rated Power In W120 W
Output Voltage24 V DC
Power Supply Output Current5 A
Complementary30
Input Voltage Limits85...264 V AC without temperature derating; 120...375 V DC without temperature derating
Nominal Network Frequency50…60 Hz
Network System CompatibilityTN; TT; IT
Maximum Leakage Current1 mA 240 V AC
Input Protection TypeIntegrated fuse (not interchangeable) 4 A; External protection (recommended) 20 A Curve C; External protection (recommended) 13 A Curve C
Inrush Current30.0 A at 115 V; 60.0 A at 230 V
Power Factor0.55 at 115 V AC; 0.45 at 230 V AC
Efficiency85 % at 115 V AC; 88 % at 230 V AC
Output Voltage Adjustment22...28 V
Power Dissipation In W25 W
Current Consumption< 2.5 A 115 V AC; < 1.4 A 230 V AC; < 1.3 A 140 V DC
Turn-on Time< 1 s
Holding Time> 20 ms 115 V AC; > 40 ms 230 V AC
Startup With Capacitive Loads8000 µF
Residual Ripple< 120 mV
Meantime Between Failure [MTBF]700000 h at 25 °C, full load conforming to SR 332
Output Protection TypeAgainst overload and short-circuits, protection technology: automatic reset; Against over temperature, protection technology: manual reset; Against overvoltage, protection technology: manual reset
Connections - TerminalsScrew connection: 0.5...4 mm², (20 AWG...12 AWG) without wire end ferrule for output; Screw connection: 0.5...2.5 mm², (20 AWG...14 AWG) with wire end ferrule for output; Screw connection: 0.75...4 mm², (18 AWG...12 AWG) without wire end ferrule for input; Screw connection: 0.75...4 mm², (18 AWG...12 AWG) with wire end ferrule for input
Line And Load Regulation< 0.5 % at 0 to 100 % load at 25 °C; < 1 % at full voltage range in line at 25 °C
Status LED1 LED (green) output voltage
Depth117.6 mm
Height123.6 mm
Width40 mm
Net Weight0.55 kg
Output CouplingParallel; Serial
Mounting SupportTop hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; Double-profile DIN rail
SupplySELV conforming to IEC 60950-1; SELV conforming to IEC 60204-1; SELV conforming to IEC 60364-4-41
Dielectric Strength3000 V AC with input to output
Service Life10 year(s)
Overvoltage CategoryII
Environment11
StandardsIEC 62368-1; EN/IEC 61204-3; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3; IEC 61000-6-4; IEC 61000-3-2; EN 61000-3-3; UL 62368-1; CSA C22.2 No 62368-1; UL 508; CSA C22.2 No 107.1
Product CertificationsCE; CUL listed; CUL recognized; RCM; CB Scheme; EAC; KC
Operating Altitude< 5000 m
Shock Resistance150 m/s² for 11 ms
IP Degree Of ProtectionIP20
Ambient Air Temperature For Operation-20…-10 °C with current derating of 2 % per °C mounting position A < 2000 m; -10…40 °C without derating mounting position A 115 V AC < 2000 m; -10…50 °C without derating mounting position A 230 V AC < 2000 m; 40…70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 2000 m; 50…70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 2000 m
Electrical Shock Protection ClassClass I
Pollution Degree2
Vibration Resistance3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6; 10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6
Electromagnetic ImmunityImmunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2; Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2; Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3; Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC
Electromagnetic EmissionConducted emissions conforming to IEC 61000-6-3; Radiated emissions conforming to IEC 61000-6-4
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.000 cm
Package 1 Width17.500 cm
Package 1 Length18.500 cm
Package 1 Weight727.000 g
Unit Type Of Package 2S03
Number Of Units In Package 213
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight10.157 kg
Unit Type Of Package 3P12
Number Of Units In Package 3312
Package 3 Height105.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight252.000 kg
Logistical informations1
Country Of OriginTH
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents3

Tags

See products with the same tag in the catalogue.