Schneider CAD32ED - Contactor: 5-pole; NC x2 + NO x3; 48VDC; 10A; TeSys D; W: 45mm; 690V
Schneider

Contactor: 5-pole; NC x2 + NO x3; 48VDC; 10A; TeSys D; W: 45mm; 690V

Schneider CAD32ED, Contactor: 5-pole; NC x2 + NO x3; 48VDC; 10A; TeSys D; W: 45mm; 690V. Category: TeSys K, D, SK Control Relays. Request a quote for price and lead time.

Key Specifications

Range
TeSys; TeSys Deca
Product Name
TeSys CAD
Product Or Component Type
Control relay
Device Short Name
CAD

Product Description

TeSys D control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 48V DC control circuit with no inrush consumption and equipped with a surge suppression device, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Key Features

  • "TeSys Control Relays provide a cost-effective solution to a simple application"
  • "Same design as TeSys D, K and SK contactors"
  • "Different ways for connection. (such as screw clamp terminal, spring terminal, welded on PCB)"
  • "Compatible for all the voltages on the market"
  • "Multiple international certifications"

Technical Specifications

Main5
RangeTeSys; TeSys Deca
Product NameTeSys CAD
Product Or Component TypeControl relay
Device Short NameCAD
Contactor ApplicationControl circuit
Complementary30
Utilisation CategoryDC-13; AC-14; AC-15
Pole Contact Composition3 NO + 2 NC
[Ue] Rated Operational Voltage<= 690 V AC 25...400 Hz
Control Circuit TypeDC standard
[Uc] Control Circuit Voltage48 V DC
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C)
Irms Rated Making Capacity140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1
[Icw] Rated Short-time Withstand Current100 A - 1 s; 120 A - 500 ms; 140 A - 100 ms
Associated Fuse Rating10 A gG conforming to IEC 60947-5-1
[Ui] Rated Insulation Voltage600 V UL certified; 600 V CSA certified; 690 V conforming to IEC 60947-5-1
Mounting SupportPlate; Rail
Connections - TerminalsScrew clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end; Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Tightening Torque1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Control Circuit Voltage Limits0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC
Operating Time53...72 ms coil energisation and NO closing; 16...24 ms coil de-energisation and NO opening; 47...63 ms coil energisation and NC opening; 15...25 ms coil de-energisation and NC closing
Mechanical Durability30 Mcycles
Maximum Operating Rate180 cyc/mn
Time Constant28 ms
Inrush Power In W5.4 W (at 20 °C)
Hold-in Power Consumption In W5.4 W at 20 °C
Minimum Switching Voltage17 V
Minimum Switching Current5 mA
Non-overlap Time1.5 ms on energisation between NC and NO contact; 1.5 ms on de-energisation between NC and NO contact
Insulation Resistance> 10 MOhm
Mechanical RobustnessShocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height77 mm
Width45 mm
Depth93 mm
Net Weight0.58 kg
Environment7
StandardsEN/IEC 60947-5-1; GB/T 14048.5; UL 60947-5-1; CSA C22.2 No 60947-5-1; JIS C8201-5-1
Product CertificationsCB; CCC; UL; CSA; EAC; CE; UKCA
IP Degree Of ProtectionIP2X front face conforming to VDE 0106
Protective TreatmentTH conforming to IEC 60068
Ambient Air Temperature For Operation-40…60 °C; 60…70 °C with derating
Ambient Air Temperature For Storage-60…80 °C
Operating Altitude0...3000 m
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.000 cm
Package 1 Width9.200 cm
Package 1 Length11.200 cm
Package 1 Weight515.000 g
Unit Type Of Package 2S02
Number Of Units In Package 215
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.016 kg
Unit Type Of Package 3P06
Number Of Units In Package 3120
Package 3 Height45.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight72.640 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents1

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support