VIGILOHM IM9 110-415VCA
Schneider IMD-IM9, VIGILOHM IM9 110-415VCA. Category: Vigilohm Insulation Monitoring Devices. Request a quote for price and lead time.
- Reference:IMD-IM9
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:383.00 EUR (Request a quote)
Key Specifications
- Range
- Vigilohm
- Device Short Name
- IM9
- Product Or Component Type
- Insulation monitoring device
- Type Of IMD
- AC IMD
Product Description
This device belongs to the Vigilohm range designed to monitor ungrounded/IT electrical networks, in accordance to installation and products standards. According to standards, it is recommanded to equip your systems with Insulation Monitoring Devices (IMD). This device is dedicated to monitoring pure AC systems of limited size, with low disturbances. It mesures the system insulation resistance by injecting a DC current between the network and ground. Configuration will be set depending on the installation. Settings are available on the front of the device. Settings are alarm and pre-alarm thresholds. It is equipped with a manual auto-test. In case the system insulation resistance drops below the set threshold, meaning a ground fault occurred, an alarm is triggered thru the IMD output relay. Once no fault is monitored, the alarm is cleared, the alarm relay is back to normal. This product can be installed on DIN rail.
Key Features
- For small IT networks without DC component
- Thresholds setting via dials on front face
- Measure the insulation resistance of the network
- Fault signalled by LED or relay outputs
Technical Specifications
Main11
| Range | Vigilohm |
|---|---|
| Device Short Name | IM9 |
| Product Or Component Type | Insulation monitoring device |
| Type Of IMD | AC IMD |
| Earthing System | IT; HRG |
| Application | Marine and offshore; Industry; Infrastructure; Power generation; Port, airport, railway |
| Network Size | Small |
| Electrical Circuit Type | Control circuit |
| Network Capacitance | Very lightly capacitive |
| Type Of Network | 1P + N; 3P; 3P + N |
| Network Rated Voltage | 0…600 V - AC at 45...440 Hz (device connected to neutral); 0…480 V - AC at 45...440 Hz (device connected to phase) |
Complementary8
| Alarm Threshold Setting | Pre-alarm: 2...500 kOhm; Alarm: 1...250 kOhm |
|---|---|
| Type Of Measurement | Network insulation resistance, range: 1000 Ohm...500 kOhm, accuracy: +/- 15 % |
| Configurable Filtering Time | 7 s |
| Response Time | <= 7 s 100 % |
| Self-test | Manual |
| Overvoltage Category | III |
| IP Degree Of Protection | Case: IP20; Front face: IP40 |
| Material | Thermoplastic |
Physical14
| Type Of Installation | Indoor |
|---|---|
| Operating Altitude | <= 3000 m |
| Relative Humidity | 0…92 % |
| Ambient Air Temperature For Operation | -25…55 °C |
| Ambient Air Temperature For Storage | -40…70 °C |
| Pollution Degree | 2 |
| Mounting Mode | Clip-on (DIN rail); Flush-mounted (panel) |
| Mounting Position | Horizontal; Vertical |
| Connections - Terminals | Tunnel type terminals 0.2…2.5 mm² |
| Net Weight | 0.2 kg |
| Cut-out Dimensions | 66 x 72.5 mm |
| Height | 90 mm |
| Width | 71 mm |
| Depth | 67.5 mm |
Communications & Management4
| Display Type | Without display |
|---|---|
| Signal Contacts Composition | 1 C/O standard or fail-safe |
| Signalling Circuit Voltage | 250 V - AC at 6 A; 12...24 V - DC at 6 A |
| Communication Of Data | HMI: test reports; Dry contact: test reports |
Power Requirements4
| [Us] Rated Supply Voltage | 110...415 V AC 50/60/400 Hz tolerance: +/- 15 %; 125...250 V DC tolerance: +/- 15 % |
|---|---|
| Power Consumption In VA | 7 VA |
| Power Consumption In W | 3 W |
| Overcurrent Protection | 1 A |
Standards4
| Standards | IEC 61557-8; UL 61010-1; IEC 61010-1; IEC 61326-2-4 |
|---|---|
| Product Certifications | EAC; CE; BV; RMRS; DNV; RCM; EU-RO MR TA |
| Environmental Characteristic | Exposure to damp heat not in service conforming to IEC 60068-2-30; Exposure to damp heat in service conforming to IEC 60068-2-56; Salt mist conforming to IEC 60068-2-52; Long-term storage class 1K22 conforming to IEC 60721-3-1; Transport class 2K11 conforming to IEC 60721-3-2; Stationary use at weather protected locations class 3K24 conforming to IEC 60721-3-3 |
| Mechanical Robustness | Long-term storage class 1M11 conforming to IEC 60721-3-1; Transport class 2M4 conforming to IEC 60721-3-2; Stationary use class 3M11 conforming to IEC 60721-3-3 |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 8.000 cm |
| Package 1 Width | 8.400 cm |
| Package 1 Length | 9.600 cm |
| Package 1 Weight | 230.000 g |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 36 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.489 kg |
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.