Schneider
LTMTPBD - TeSys Tera Main Module Profibus 24VDC
Schneider LTMTPBD, TeSys Tera Main Module Profibus 24VDC. Category: TeSys Tera. Request a quote for price and lead time.
- Reference:LTMTPBD
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:1,087.80 EUR (Request a quote)
Key Specifications
- Range
- TeSys
- Product Name
- TeSys Tera
- Device Short Name
- LTMT
- Product Or Component Type
- Motor controller
Product Description
- TeSys Tera Motor Management system and protection system is designed to provide high performance, efficiency, and connectivity.
- 24 VDC is used to power this controller.
- PROFIBUS DP Communication with DP0 cyclic services and DP1 acyclic services
- This module has 4 digital inputs and 3 digital outputs.
- baud rate detection 12 Mbit/s on D-Type connector and 1.5 Mbit/s on terminal.
- And provide complete protection, control, and monitoring capabilities for single-phase and three-phase AC induction motors up to 810A.
- Advance notice of potential issues through intuitive pre-trip alarming.
- Connection via a communication network.
- It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions.
- Controller has the following certifications: IEC, UL, cUL.
Key Features
- Current and voltage-based protections
- Motor parameters monitoring and protection
- Profibus DP Communication
- 24V DC Control voltage
- Time synchronisation Configuration
Technical Specifications
Main10
| Range | TeSys |
|---|---|
| Product Name | TeSys Tera |
| Device Short Name | LTMT |
| Product Or Component Type | Motor controller |
| Device Application | Equipment monitoring and control |
| [Us] Rated Supply Voltage | 24 V DC |
| Current Consumption | 56...127 mA |
| Supply Voltage Limits | 18…30 V DC |
| Communication Port Protocol | Profibus DP |
| Bus Type | Profibus DP 2-wire RS 485 interface, addressing 1...125, transmission rate 9.6 kbit/s...12 Mbit/s, SUB-D 9 with 2 shielded twisted pairs; Profibus DP 2-wire RS 485 interface, addressing 1...125, transmission rate 1.5 Mbit/s, terminal block with 2 shielded twisted pairs |
Complementary26
| [Ui] Rated Insulation Voltage | 24 V DC conforming to IEC 60185 |
|---|---|
| Short-circuit Withstand | 100 kA |
| Pollution Degree | 3 |
| Overvoltage Category | III |
| [Uimp] Rated Impulse Withstand Voltage | 0.8 kV |
| Associated Fuse Rating | 0.5 A gG for control circuit |
| Protection Type | Overload protection; Stalled rotor; Locked rotor; Short-circuit; Undercurrent; Overcurrent; Current unbalance; Phase reversal; Phase loss; Earth fault protection internal; Earth fault protection external; Excessive starting time; Max number of start; Undervoltage; Overvoltage; Voltage unbalance; Underfrequency; Overfrequency; Reacceleration; Temperature protection; Analog input protection; Communi |
| Network And Machine Diagnosis Type | Motor statistics; Motor status; Event recording; Running hours counter/operating time; Number of starts and stops; Running hours /stop hours counter; Start curve showing motor start record; Pre-alarms; Trip history information; Alarm counters |
| Logic Input Number | 4 |
| Input Current | 2.5 mA at 24 V |
| Current State 0 Guaranteed | Digital input: 0...12 V and 5 mA for 10 ms |
| Current State 1 Guaranteed | Digital input: 18...30 V and 5 mA for 10 ms |
| Maximum Output Switching Frequency | 2 Hz |
| Load Current | 10 A at 250 V AC/DC; 5 A at 30 V DC |
| Permissible Power | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output); 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
| Maximum Operating Rate | 1800 cyc/h |
| Contacts Type And Composition | 2 NO fault signal; 1 NO + 1 NC fault signal |
| Metering Type | Thermal memory; Line, phase and average current; Line to line and average voltage; Motor temperature input; Ground fault current Ig; Active and reactive power; Active and reactive energy; Frequency; Total voltage harmonic distortion THD (V); Total voltage harmonic distortion THD (U); Total current harmonic distortion THD (I); Phase sequence |
| Measurement Accuracy | 1 % current (0.3...3 A); 1 % current (2.5...25 A); 3 % current (7...70 A); 3 % current (10...100 A); 1 % voltage (110...690 V); +/- 2.5 % earth fault current external measurement; +/- 3...5 % earth fault current internal measurement (current > 0.03 A in the 0.3...3 A range); +/- 3...5 % earth fault current internal measurement (current > 0.25 A in the 2.5...25 A range); +/- 3...5 % earth fault cur |
| Connection Pitch | 7.5 mm for supply voltage; 5.0 mm for others |
| Connections - Terminals | Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG...14 AWG) flexible with ferrule with cable end; Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG...14 AWG) flexible with ferrule with cable |
| Tightening Torque | Control circuit: 0.5 N.m - with screwdriver flat 3 mm |
| Width | 112 mm |
| Height | 45 mm |
| Depth | 90 mm |
| Web Services | Web server |
Environment8
| Standards | EN/IEC 60947-4-1; UL/CSA 60947-4-1 |
|---|---|
| Product Certifications | UL; IEC; cUL |
| Fire Resistance | 650 °C conforming to IEC 60947-1; 960 °C conforming to UL 94 |
| Ambient Air Temperature For Operation | -20…70 °C |
| Ambient Air Temperature For Storage | -40…80 °C |
| Operating Altitude | <= 2000 m without derating |
| Mechanical Robustness | Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-27; Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6; Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |
| IP Degree Of Protection | IP20 |
Packing Units18
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 6.5 cm |
| Package 1 Width | 10.5 cm |
| Package 1 Length | 11 cm |
| Package 1 Weight | 295.5 g |
| Unit Type Of Package 2 | S01 |
| Number Of Units In Package 2 | 4 |
| Package 2 Height | 15 cm |
| Package 2 Width | 15 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 1.623 kg |
| Unit Type Of Package 3 | P06 |
| Number Of Units In Package 3 | 192 |
| Package 3 Height | 1050 cm |
| Package 3 Width | 60 cm |
| Package 3 Length | 80 cm |
| Package 3 Weight | 68.736 kg |
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.