Key Specifications

Range
TeSys
Product Name
TeSys Ultra
Device Short Name
LUB
Product Or Component Type
Non reversing power base

Product Description

  • TeSys U standard power base, 3 poles (3NO), 38A/690V, to be completed with a control unit LUC to form a TeSys U starter controller, for 3-phase motor applications up to 18.5kW@400V.
  • Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" starter controller with basic or advanced protection and control functions.
  • It is equipped with a control terminal block, and blanking shutters covering the empty cavities.
  • It provides a high breaking capacity Icu 25kA@400V, start-stop control guaranteed for 3600 cycles/hour.
  • Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle.
  • Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine)

Key Features

  • "Number of direction of rotation to be controlled is 1"
  • "Type of control to be achieved is Basic control"
  • "Modular, plug & play structure helps you to perform quick maintenance"
  • "Direct access to detailed information for every motor starter of your installation"
  • "Advanced motor management system"

Technical Specifications

Main16
RangeTeSys
Product NameTeSys Ultra
Device Short NameLUB
Product Or Component TypeNon reversing power base
Device ApplicationMotor control; Motor protection
Poles Description3P
Suitability For IsolationYes
[Ue] Rated Operational Voltage690 V AC for power circuit
Network Frequency40...60 Hz
[Ith] Conventional Free Air Thermal Current38 A
[Ie] Rated Operational Current35 A at <= 440 V; 28 A at 500 V; 24 A at 690 V
Utilisation CategoryAC-43; AC-41
[Ics] Rated Service Breaking Capacity25 kA at 230 V; 25 kA at 440 V; 10 kA at 500 V; 4 kA at 690 V
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Typetype linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1; type mirror contact (1 NC) conforming to IEC 60947-1
[Uc] Control Circuit Voltage24 V AC 50/60 Hz; 24 V DC; 48...72 V AC 50/60 Hz; 48...72 V DC; 110...240 V AC 50/60 Hz; 110...220 V DC
Complementary19
Typical Current Consumption200 mA at 24 V DC I maximum while closing with LUCM; 220 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD; 220 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD; 25 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD; 25 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD; 280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, L
Heat Dissipation3 W for control circuit with LUCA, LUCB, LUCC, LUCD; 1.8 W for control circuit with LUCM
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating Time35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit; 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit; 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit; 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit; 65 ms closing with LUCM for control circuit
Mechanical Durability15 Mcycles
Maximum Operating Rate3600 cyc/h
Product CertificationsCE; UL; CSA; CCC; EAC
StandardsEN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
[Ui] Rated Insulation Voltage690 V conforming to IEC 60947-6-2 (pollution degree 3); 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-6-2
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Fixing ModeClipped (DIN rail); Screw-fixed (plate)
Connections - TerminalsControl circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigid; Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm²
Tightening TorqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm; Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
Width45 mm
Height154 mm
Depth126 mm
Net Weight0.9 kg
Compatibility CodeLUB
Environment15
IP Degree Of ProtectionIP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective TreatmentTH conforming to IEC 60068
Ambient Air Temperature For Operation-25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient Air Temperature For Storage-40…85 °C
Fire Resistance960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Operating Altitude2000 m
Shock Resistance10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration Resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance To Electrostatic Discharge8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating Shock Wave1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2; 1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2; 2 kV common mode 24...240 V AC conforming to IEC 60947-6-2; 2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
Resistance To Fast Transients2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance To Radiated Fields10 V/m 3 conforming to IEC 61000-4-3
Immunity To Radioelectric Fields10 V conforming to IEC 61000-4-6
Immunity To Microbreaks3 ms for control circuit
Immunity To Voltage Dips70 % / 500 ms conforming to IEC 61000-4-11
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.200 cm
Package 1 Width17.000 cm
Package 1 Length14.500 cm
Package 1 Weight848.000 g
Unit Type Of Package 2S02
Number Of Units In Package 210
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.756 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18