Schneider LV429797 - Circuit breaker, ComPact NSX100N, 50kA/415VAC, MicroLogic 2.2 trip unit 40A, 3 poles 3d
Schneider

Circuit breaker, ComPact NSX100N, 50kA/415VAC, MicroLogic 2.2 trip unit 40A, 3 poles 3d

Not for sale

Schneider LV429797, Circuit breaker, ComPact NSX100N, 50kA/415VAC, MicroLogic 2.2 trip unit 40A, 3 poles 3d. Category: ComPact NSX <630A. Not for sale; no price or quote is offered for this product.

Key Specifications

Range
ComPact
Product Name
ComPact NSX
Range Of Product
ComPact NSX100...250
Device Short Name
NSX100N

Product Description

This Compact NSX100N is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds an electronic Micrologic 2.2 trip unit, with 40A rating. Micrologic 2.2 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. Compact NSX100N is part of Schneider Electric EcoStruxure Power architecture.

Technical Specifications

Main21
RangeComPact
Product NameComPact NSX
Range Of ProductComPact NSX100...250
Device Short NameNSX100N
Product Or Component TypeCircuit breaker
Device ApplicationDistribution
Number Of Poles3P
Protected Poles Description3t
[In] Rated Current40 A at 40 °C
[Ue] Rated Operational Voltage690 V AC 50/60 Hz
Network TypeAC
Network Frequency50/60 Hz
Suitability For IsolationYes conforming to EN/IEC 60947-2
Utilisation CategoryCategory A
[Icu] Rated Ultimate Short-circuit Breaking Capacity85 kA at 240 V AC 50/60 Hz conforming to UL 508; 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2; 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2; 20 kA at 600 V AC 50/60 Hz conforming to UL 508; 50 kA at 480 V AC 50/60 Hz conforming to UL 508; 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 50 kA Icu at
Performance LevelN 50 kA 415 V AC
Trip Unit NameMicroLogic 2.2
Trip Unit TechnologyElectronic
Trip Unit Protection FunctionsLSoI
Control TypeToggle
Circuit Breaker Mounting ModeFixed
Complementary29
[Ui] Rated Insulation Voltage800 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ics] Rated Service Short-circuit Breaking Capacity10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2; 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2; 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2; 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2; 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical Durability50000 cycles
Electrical Durability10000 cycles at 690 V In; 20000 cycles at 690 V In/2; 30000 cycles at 440 V In; 50000 cycles at 440 V In/2
Mounting SupportBackplate
Upside ConnectionFront
Downside ConnectionFront
Connection Pitch35 mm
Protection TypeL : for overload protection (long time); So : for short time short-circuit protection with fixed delay; I : for instantaneous short-circuit protection
Trip Unit Rating40 A at 40 °C
Long-time Pick-up Adjustment Type Ir (thermal Protection)Adjustable 9 settings
[Ir] Long-time Protection Pick-up Adjustment Range18...40 A
Long-time Protection Delay Adjustment Type TrFixed
[tr] Long-time Protection Delay Adjustment Range11 s at 7.2 x Ir; 16 s at 6 x Ir; 400 s at 1.5 x Ir
Thermal Memory20 minutes before and after tripping
Short-time Protection Pick-up Adjustment Type IsdAdjustable 9 settings
[Isd] Short-time Protection Pick-up Adjustment Range1.5...10 x Ir
Short-time Protection Delay Adjustment Type TsdFixed
Instantaneous Protection Pick-up Adjustment Type IiFixed
[Ii] Instantaneous Protection Pick-up Adjustment Range600 A
Earth-leakage ProtectionWithout
Zone Selective Interlocking ZSIWithout
Number Of Slots For Electrical Auxiliaries5 slot(s)
Local SignallingFlashing LED (green) for ready to operate; LED 105 % Ir (red) for overload; LED 90 % Ir (orange) for overload
Width (W)105 mm
Height (H)161 mm
Depth (D)86 mm
Net Weight2.05 kg
Environment11
StandardsEN/IEC 60947
Product CertificationsCCC; EAC; Marine
Overvoltage CategoryClass II
Electrical Shock Protection ClassClass II
Pollution Degree3 conforming to IEC 60664-1
IP Degree Of ProtectionIP40 conforming to IEC 60529
IK Degree Of ProtectionIK07 conforming to IEC 62262
Ambient Air Temperature For Operation-25…70 °C
Ambient Air Temperature For Storage-50…85 °C
Relative Humidity0…95 %
Operating Altitude0...2000 m without derating; 2000 m...5000 m with derating
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height11.0 cm
Package 1 Width14.0 cm
Package 1 Length19.0 cm
Package 1 Weight1.852 kg
Unit Type Of Package 2S03
Number Of Units In Package 26
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.532 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents3

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support