Key Specifications

Series
Compact
Product Name
Compact NSX
Product Or Component Type
Circuit breaker
Device Short Name
Compact NSX250H

Product Description

Schneider LV431170 (LV431170).

Technical Specifications

SeriesCompact
Product NameCompact NSX
Product Or Component TypeCircuit breaker
Device Short NameCompact NSX250H
Device ApplicationMotor
Poles Description3P
Protected Poles Description3t
Network TypeAC
Network Frequency50/60 Hz
[In] Rated Current220 A ( 65 °C ), 250 A ( 40 °C )
[Ui] Rated Insulation Voltage800 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ue] Rated Operational Voltage690 V AC 50/60 Hz
Suitability For IsolationH
Breaking Capacity-de 240 V AC 50/60 Hz uyumluluk standardı NEMA AB1, 15 kA -de 600 V AC 50/60 Hz uyumluluk standardı UL 508, -de 600 V AC 50/60 Hz uyumluluk standardı NEMA AB1, -de 480 V AC 50/60 Hz uyumluluk standardı NEMA AB1, 65 kA -de 480 V AC 50/60 Hz uyumluluk standardı UL 508, 85 kA -de 240 V AC 50/60 Hz uyumluluk standardı UL 508, 50 kA Icu -de 500 V AC 50/60 Hzuyumluluk standardı IEC 60947-2, 10 kA Icu -d
[Ics] Rated Service Breaking CapacityIcs 10 kA 660/690 V AC 50/60 Hz uyumluluk standardı IEC 60947-2, Ics 100 kA 220/240 V AC 50/60 Hzuyumluluk standardı IEC 60947-2, Ics 35 kA 525 V AC 50/60 Hzuyumluluk standardı IEC 60947-2, Ics 50 kA 500 V AC 50/60 Hzuyumluluk standardı IEC 60947-2, Ics 65 kA 440 V AC 50/60 Hzuyumluluk standardı IEC 60947-2, Ics 70 kA 380/415 V AC 50/60 Hzuyumluluk standardı IEC 60947-2
Isolator SuitabilityEvetuyumluluk standardı EN 60947-2, Evetuyumluluk standardı IEC 60947-2
Utilization CategoryCategory A
Trip Unit NameMicrologic 2.2 M
Trip Unit TechnologyElectronic
Trip Unit Protection FunctionsLSoI
Trip Unit Rating220 A ( 65 °C )
Protection TypeAnlık kısa devre koruması, Aşırı yük koruma (uzun süreli), Kısa süreli kısa devre koruması
Pollution Degree3uyumluluk standardı IEC 60664-1
Control TypeToggle
Mounting ModeFixed
Mounting SupportBackplate
Upper ConnectionFront
Lower ConnectionFront
Mechanical Durability20000 cycles
Electrical Durability10000 cycles 440 V In uyumluluk standardı IEC 60947-2, 10000 cycles 690 V In/2 uyumluluk standardı IEC 60947-2, 20000 cycles 440 V In/2 uyumluluk standardı IEC 60947-2, 5000 cycles 690 V In uyumluluk standardı IEC 60947-2
Connection Pitch35 mm
Local SignalingLED % 95 Ith, LED ready
Motor Trip Class10, 20, 5
Complementary Motor ProtectionPhase unbalance
Long-time Pick-up Adjustment Type LrAdjustable 9 settings
Long-time Pick-up Adjustment Range100...220 A
Long-time Delay Adjustment TypeFixed
[tr] Long-time Delay Adjustment10 s 7,2 x Ir 10, 120 s 1,5 x Ir 5, 20 s 7,2 x Ir 20, 240 s 1,5 x Ir 10, 26 s 6 x Ir 20, 480 s 1,5 x Ir 20, 5 s 7,2 x Ir 5, 13,5 sn 6 x Ir 10, 6,5 sn 6 x Ir 5
Thermal Memory20 minutes before and after tripping
Short-time Pick-up Adjustment Type IsdAdjustable 9 settings
[Isd] Short-time Pick-up Adjustment Range5...13 x Ir
Short-time Delay Adjustment TypeFixed
Instantaneous Pick-up Adjustment Type LiFixed
Instantaneous Pick-up Adjustment Range3300 A
Height161 mm
Width105 mm
Depth86 mm
Product Weight2.4 kg
Electric Shock Protection ClassClass II
StandardsEN 60947-2, IEC 60947-2, NEMA AB1, UL 508
Product CertificationsCSA, UL
IP Degree Of ProtectionIP40uyumluluk standardı IEC 60529
IK Degree Of ProtectionIK07uyumluluk standardı IEC 62262
Ambient Air Temperature For Operation-35...70 °C
Ambient Air Temperature For Storage-55...85 °C
Sustainable Offer StatusGreen Premium product
ROHSCompliant - since 0819 - Schneider Electric declaration of conformity
REACHReference not containing SVHC above the threshold
Product Environmental ProfileAvailable