Schneider LV510310 - Schneider Thermal-Magnetic Circuit Breaker
Schneider

Schneider LV510310 Thermal-Magnetic Circuit Breaker

Schneider LV510310, Schneider Thermal-Magnetic Circuit Breaker. Category: Compact-type circuit breakers with thermal-magnetic trip. Request a quote for price and lead time.

Key Specifications

Product Range
Easypact CVS100...250
Product Or Component Type
Circuit breaker
Device Short Name
CVS100B
Device Application
Distribution

Product Description

Schneider LV510310 thermal-magnetic molded case circuit breaker is supplied by UC-EL Electric. Apply for a price quotation.

Technical Specifications

Product RangeEasypact CVS100...250
Product Or Component TypeCircuit breaker
Device Short NameCVS100B
Device ApplicationDistribution
Poles Description4P
Protected Poles Description3d
Neutral PositionLeft
Earth Leakage ProtectionNone
[In] Rated Current100 A ( 40 °C )
Rating CodeB
Network TypeAC
[Ue] Rated Operational Voltage440 V ACcompliance standard EN/IEC 60947-2 50/60 Hz
Breaking Capacity40 kA Icucompliance standard IEC 60947-2 at 220/240 V AC 50/60 Hz, 20 kA Icucompliance standard IEC 60947-2 at 440 V AC 50/60 Hz, 25 kA Icucompliance standard IEC 60947-2 at 380/415 V AC 50/60 Hz
Utilization CategoryCategory A
Trip Unit NameTM-D
Trip Unit TechnologyThermal-magnetic
Trip Unit Rating16 A ( 40 °C )
Protection TypeOverload protection (thermal), Short-circuit protection (magnetic)
Network Frequency50/60 Hz
Control TypeToggle
Mounting ModeFixed
Mounting SupportBackplate
Upside ConnectionFront
Downside ConnectionFront
[Ui] Rated Insulation Voltage690 Vcompliance standard EN/IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage8 kVcompliance standard EN/IEC 60947-2
[Ics] Rated Service Breaking Capacity15 kAcompliance standard IEC 60947-2 440 V AC 50/60 Hz, 25 kAcompliance standard IEC 60947-2 380/415 V AC 50/60 Hz, 40 kAcompliance standard IEC 60947-2 220/240 V AC 50/60 Hz
Mechanical Durability30000 cycles
Electrical Durability12000 cyclescompliance standard IEC 60947-2 415 V In
Connection Pitch35 mm
Contact Position IndicatorYes
Neutral Protection SettingWithout protection 3d
Long-time Pick-up Adjustment Type LrAdjustable
Long-time Pick-up Adjustment Range0,7...1 x In
Long-time Delay Adjustment TypeFixed
Short-time Delay Adjustment TypeFixed
Instantaneous Pick-up Adjustment Type LiFixed
Instantaneous Pick-up Adjustment Range190 A
Height161 mm
Width140 mm
Depth86 mm
Electric Shock Protection ClassClass II
StandardsEN 60947-2, IEC 60947-2
Product CertificationsGOST, IEC
Pollution Degree3compliance standard IEC 60947-1
Ambient Air Temperature For Operation-25...70 °C
Ambient Air Temperature For Storage-50...85 °C
Sustainable Offer StatusNot a Green Premium product
ROHSCompliant - since 1041 - Schneider Electric declaration of conformity
REACHReference not containing SVHC above the threshold
Product Environmental ProfileAvailable

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support