Schneider METSEPM5350 - PM5350, 0.5S, 15th harmonic, 4DI/2DO, Modbus serial connection
Schneider

METSEPM5350 - PM5350, 0.5S, 15th harmonic, 4DI/2DO, Modbus serial connection

Schneider METSEPM5350, PM5350, 0.5S, 15th harmonic, 4DI/2DO, Modbus serial connection. Category: PowerLogic PM5000. Request a quote for price and lead time.

Key Specifications

Range
PowerLogic
Product Name
PowerLogic PM5350
Product Or Component Type
Power meter
Device Short Name
PM5350

Product Description

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. Include a non-volatile memory for several parameters and alarms. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 85 to 265 VAC and 100 to 300 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20V AC to 480V AC, CAT III or 20V AC to 690V AC, CAT II at 45 Hz to 70 Hz. The range of measurement voltage between Phase and Neutral is 20V AC to 277V AC, CAT III or 20V AC to 400V AC, CAT II at 45 Hz to 70 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has four digital inputs and dual relay outputs. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.24 inches (57 millimetres), height 3.78 inches (96 millimetres) and product weight 8.8 onces (250 g).

Key Features

  • "Feature-rich power and energy meters"
  • "Identify energy savings opportunties with precision accuracy of Class 0.5S"
  • "Total Harmonic Distortion for Power Quality management"
  • "Full scape graphical LCD for clear viewing"

Technical Specifications

Main4
RangePowerLogic
Product NamePowerLogic PM5350
Product Or Component TypePower meter
Device Short NamePM5350
Complementary32
Power Quality Analysistotal demand distortion; total harmonic distortion
Device ApplicationPower monitoring
Type Of MeasurementCurrent; Voltage; Frequency; Power factor; Energy; Apparent power; Active power; Reactive power
[Us] Rated Supply Voltage85...265 V AC 45...65 Hz; 100...300 V DC
Network Frequency50 Hz; 60 Hz
[In] Rated Current5 A; 1 A
Type Of Network1P + N; 3P + N; 3P
Maximum Power Consumption In VA11.9 VA
Ride-through Time100 ms 120 V AC typical; 400 ms 230 V AC typical; 50 ms 125 V DC typical
Display TypeMonochrome graphic LCD
Display Resolution6 lines
Sampling Rate32 samples/cycle
Measurement Current5…9000 mA
Analogue Input TypeCurrent 0.05...9 A (impedance <= 0.3 mOhm); Voltage (impedance 10 MOhm)
Measurement Voltage35…480 V AC 45...65 Hz phase to phase; 20…277 V AC phase to neutral
Frequency Measurement Range45…70 Hz
Number Of Inputs4 digital
Measurement AccuracyCurrent +/- 0.3 %; Voltage +/- 0.3 %; Frequency +/- 0.05 %; Power factor +/- 0.005; Active energy +/- 0.5 %; Reactive energy +/- 2 %; Active power +/- 0.5 %; Apparent power +/- 0.5 %; Apparent energy +/- 0.5 %; Reactive power +/- 2 %
Accuracy ClassClass 0.5S active energy conforming to IEC 62053-22; Class 0.5 active energy conforming to IEC 61557-12; Class 2 reactive energy conforming to IEC 62053-23; Class 2 reactive energy conforming to IEC 61557-12; Class 0.5 power conforming to IEC 61557-12
Number Of Outputs2 relay
Communication Port ProtocolJBUS; Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds
Communication Port SupportTerminal block: RS485
Data RecordingMin/max of instantaneous values; Alarms
Connections - TerminalsVoltage circuit: screw terminal block4; Control circuit: screw terminal block2; Current transformer: screw terminal block6; Input/output circuit: screw terminal block6; Relay output: screw terminal block4
Mounting ModeFlush-mounted
Type Of InstallationFor indoor use in a stationary panel
StandardsIEC 61010-1
Product CertificationsCE; CULus
Width96 mm
Depth44 mm
Height96 mm
Net Weight0.25 kg
Environment8
Electromagnetic CompatibilityLimitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3; Electrostatic discharge conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test conforming to IEC 61000-4-4; 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5; Conducted RF disturbances con
Overvoltage CategoryIII
IP Degree Of ProtectionIP30 rear: conforming to IEC 60529; IP54 display: conforming to IEC 60529
Relative Humidity5…95 % at 50 °C non-condensing
Pollution Degree2
Ambient Air Temperature For Operation-25…70 °C meter; -20…70 °C display; -25…-20 °C (with reduced performance) display
Ambient Air Temperature For Storage-40…85 °C
Operating Altitude<= 3000 m
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height11.200 cm
Package 1 Width12.500 cm
Package 1 Length12.700 cm
Package 1 Weight346.000 g
Unit Type Of Package 2S03
Number Of Units In Package 212
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.829 kg
Logistical informations1
Country Of OriginIN
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents6