Key Specifications

Range Of Product
Harmony Control Relays
Relay Type
Multifunction control relay
Product Or Component Type
3-phase control relay
Relay Name
RM17TA

Product Description

This Harmony RM17-TA relay allows monitoring of power supply circuits in 3-phase networks. This modular multi function 3-phase supply control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. The product monitors its own power supply, when the power supply is abnormal, the output relay de-energizes. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.

Key Features

  • "Simplified panel design due to 17.5mm width same as 1-pole circuit breaker"
  • "Experience unprecedented accuracy, predictive maintenance, and superior security."
  • "The product monitors its own power supply. When the power supply is abnormal, the output relay de-energizes"
  • "Transparent cover to protect settings from being tampered with reducing maintenance"
  • "Compatible with a wide range of applications, such as hoisting, packaging, lifts, textile, pumping, and water."

Technical Specifications

Main9
Range Of ProductHarmony Control Relays
Relay TypeMultifunction control relay
Product Or Component Type3-phase control relay
Relay NameRM17TA
Relay Monitored ParametersAsymmetry; Phase sequence; Phase failure detection
Control TypeWithout test button
Contacts Type And Composition1 C/O
[Uc] Control Circuit Voltage208...480 V
Product Specific ApplicationFor 3-phase supply
Complementary24
[Us] Rated Supply Voltage, self-powered
Supply Voltage Limits183…528 V AC
Supply Frequency50/60 Hz +/- 10 %
Power Consumption In VA0…22 VA at 400 V AC 50 Hz
Measurement Range208...480 V AC
Measurement Voltage Limits183…528 V AC
Maximum Measuring Cycle150 ms measurement cycle as true rms value
Hysteresis2 %
Adjustment Of Asymmetry Threshold5...15 % of Un selected
Measurement Error< 0.05 %/°C with temperature variation; < 1 % over the whole range with voltage variation
Time Delay TypeAdjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault
Reset Time1500 ms time delay
Response Time< 200 ms (in the event of a fault)
Output Contacts1 C/O
Nominal Output Current5 A
Maximum Switching Voltage250 V AC
Switching Capacity In VA1250 VA
Minimum Switching Current10 mA at 5 V DC
Maximum Switching Current5 A AC; 5 A DC
Electrical Durability100000 cycles
Mechanical Durability30000000 cycles
Control Circuit Voltage Limits- 12 % + 10 % Un
Control Circuit Frequency50...60 Hz +/- 10 %
Phase Failure Sensitivity0.7 Un
Environment25
Electromagnetic CompatibilityEmission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to IEC 61000-6-2
StandardsIEC 60255-1
Product CertificationsGOST; CSA; GL; C-Tick; UL
MarkingCE
Directives89/336/EEC - electromagnetic compatibility; 73/23/EEC - low voltage directive
Ambient Air Temperature For Storage-40…70 °C; -40…70 °C
Ambient Air Temperature For Operation-20…50 °C
Relative Humidity95 % at 55 °C conforming to IEC 60068-2-30
IP Degree Of ProtectionIP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529
Pollution Degree3 conforming to IEC 60664-1
Overvoltage CategoryIII conforming to IEC 60664-1
Dielectric Test Voltage2 kV, 1 min AC 50 Hz conforming to IEC 60255-5
Insulation Resistance> 500 MOhm at 500 V DC conforming to IEC 60255-5
[Ui] Rated Insulation Voltage400 V conforming to IEC 60664-1
Operating PositionAny position without derating
Connections - TerminalsScrew terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end
Tightening Torque0.6…1 N.m conforming to IEC 60947-1
Housing MaterialPolycarbonate
Local SignallingLED (green) for power ON; LED (yellow) for relay ON
Mounting Support35 mm symmetrical DIN rail conforming to IEC 60715
Reliability DataMTTFd = 502.2 years; B10d = 470000
Height90 mm; 88.9 mm
Width17.5 mm; 17.8 mm
Depth72 mm; 71.1 mm
Net Weight0.08 kg; 0.08 kg
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height2.800 cm
Package 1 Width7.800 cm
Package 1 Length9.600 cm
Package 1 Weight92.000 g
Unit Type Of Package 2S02
Number Of Units In Package 248
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.700 kg
Logistical informations1
Country Of OriginID
Contractual warranty1