Schneider VPL06N - Microprocessor 6-step, Modbus SL, dual Cosⱷ
Schneider

VPL06N - Microprocessor 6-step, Modbus SL, dual Cosⱷ

Schneider VPL06N, Microprocessor 6-step, Modbus SL, dual Cosⱷ. Category: PowerLogic™ PFC Power Factor Correction Controllers. Request a quote for price and lead time.

Key Specifications

Range
PowerLogic
Product Name
PowerLogic PFC Controller
Product Or Component Type
Power factor controller
Device Short Name
VPL6

Product Description

  • VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor.
  • It is a simple and intelligent relay which measures,monitor and Controls the reactive energy.
  • It comes with Easy Commisioning , Step Size detection and monitoring along with the variour alarms.
  • VPL06 can be used for 6 steps in a PFC equippment

Key Features

  • "Power Controller for an automatic power factor correction equipment to maintain the power factor"
  • "Simple and efficient with ready to connect with RS485 modbus communication"
  • "Best in class performance, safety and reliability"

Technical Specifications

Main4
RangePowerLogic
Product NamePowerLogic PFC Controller
Product Or Component TypePower factor controller
Device Short NameVPL6
Complementary36
Number Of Step Output Contacts6
[Us] Rated Supply Voltage90...550 V AC; <= 999 kV AC with external VT
Measurement Current0…5 A
Measurement Voltage90…550 V AC 50/60 Hz
Operating ModeManual or automatic
Number Of Quadrant Operation For Generator Application4
Device ConnectionCommunication protocol: Modbus interface: RS485
Input FunctionSwitch: 1 x dry contact
Colour CodeFront: dark grey RAL 7016
Display TypeBacklit LCD
Display Size56 x 25 mm
Function AvailableAutomatic detection; Advanced programming (expert); Manual programming; Any step sequence; Automatic initialisation
Metering TypePower factor and displacement PF (signed, four quadrant); Total current harmonic distortion THD (I); Power factor average over lifetime; Temperature maximum; Phase current I1, I2, I3 RMS on load; Active power P, P1, P2, P3 on load; Reactive power Q, Q1, Q2, Q3 on load; Apparent power S, S1, S2, S3 on load; Voltage U21, U32, U13, V1, V2, V3 on load
Type Of MeasurementAmbient temperature inside the cubicle; Tan φ; Individual voltage harmonic; Cos φ; Operating time; Power factor; Capacitor current overload Irms/I1
Information DisplayedNumber of switching cycles per step; Remaining step capacity in %; Individual step size in kVAr
Type Of AlarmsStep power loss (< 75 %) / Action: message and alarm contact + step blocked; Step faulty / Action: message and alarm contact + step blocked; High current (> 6 A CT) / Action: message and alarm contact; Hunting (unstable regulation) / Action: message and alarm contact + step blocked; Low current (< 15 mA CT) / Action: message and alarm contact; Overcompensation / Action: message and alarm contact;
Data Recording5 alarms
Operational Hours Alarm100000 h without maintenance
Operational Counter Alarm65000 cycles without maintenance
Input TypeInsensitive to phase rotation polarity; Insensitive to CT polarity; Phase to neutral; Current input CT...X/5 A and X/1 A; Phase to phase
Output TypeControl relay: 0.2 A 110 V DC; Control relay: 1 A 48 V DC; Control relay: 2 A 400 V AC 50/60 Hz; Control relay: 1 A 24 V DC; Control relay: 5 A 250 V AC 50/60 Hz; Control relay: 5 A 120 V AC 50/60 Hz; Fan: 5 A 250 V AC 50/60 Hz; Fan: 1 A 48 V DC; Alarm relay: 5 A 250 V AC 50/60 Hz; Alarm relay: 1 A 48 V DC
Maximum At The Common Terminal10 A
Settings Operating ModeManual; Automatic
Type Of SettingChoice of stepping programs: auto; Choice of stepping programs: LIFO; Choice of stepping programs: linear; Delay between 2 successive switch on the same step: 5...1200 s; Step configuration programming: auto; Step configuration programming: off; Step configuration programming: fixed; Target cos phi: 0.7 inductive...0.7 capacitive; Target cos phi: dual cos φ
Measurement AccuracyVoltage +/- 1 %; Current +/- 1 %; Frequency +/- 1 %; Energy (P,Q,S) +/- 2 %; Cos φ +/- 2 %; Total voltage harmonic distortion THD (U) +/- 2 %; Individual voltage harmonic +/- 3 %; Temperature +/- 3 °C
Time Delay Range1...6500 s (on reconnection); 1...6500 s (on response)
Provided EquipmentUser manual
Mounting ModeFlush-mounted
Mounting SupportPanel - thickness: 1…3 mm
Mounting LocationIn cabinet
Cut-out Dimensions138 x 138 mm
Height144 mm
Width144 mm
Depth58 mm
Net Weight0.6 kg
Compatibility CodeVPL 6
Environment6
StandardsIEC 61000-6-2; EN 61010-1; IEC 61000-6-4; IEC 61326-1; UL 61010-1
Product CertificationsEAC; NRTL; cNRTL; CE
IP Degree Of ProtectionFront face: IP41; Rear face: IP20
Operating Altitude<= 2000 m
Ambient Air Temperature For Operation-20…60 °C
Ambient Air Temperature For Storage-40…85 °C
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height9.200 cm
Package 1 Width17.800 cm
Package 1 Length18.400 cm
Package 1 Weight696.000 g
Unit Type Of Package 2S03
Number Of Units In Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.050 kg
Unit Type Of Package 3P06
Number Of Units In Package 364
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight60.348 kg
Logistical informations1
Country Of OriginDE
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents3

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support