Schneider VPL12N - Microprocessor 12-step, Modbus SL, dual Cosⱷ
Schneider

VPL12N - Microprocessor 12-step, Modbus SL, dual Cosⱷ

Schneider VPL12N, Microprocessor 12-step, Modbus SL, dual Cosⱷ. Category: PowerLogic™ PFC Power Factor Correction Controllers. Request a quote for price and lead time.

Key Specifications

Range
PowerLogic
Product Name
PowerLogic PFC Controller
Product Or Component Type
Power factor controller
Device Short Name
VPL12

Product Description

VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor. It is a simple and intelligent relay which measures,monitor and Controls the reactive energy. It comes with Easy Commisioning , Step Size detection and monitoring along with the variour alarms. VPL12 can be used for 12 steps in a PFC equippment.

Key Features

  • "Power Controller for an automatic power factor correction equipment to maintain the power factor"
  • "Simple and efficient with ready to connect with RS485 modbus communication"
  • "Best in class performance, safety and reliability"

Technical Specifications

Main4
RangePowerLogic
Product NamePowerLogic PFC Controller
Product Or Component TypePower factor controller
Device Short NameVPL12
Complementary36
Number Of Step Output Contacts12
[Us] Rated Supply Voltage90...550 V AC; <= 999 kV AC with external VT
Measurement Current0…5 A
Measurement Voltage90…550 V AC 50/60 Hz
Operating ModeManual or automatic
Number Of Quadrant Operation For Generator Application4
Device ConnectionCommunication protocol: Modbus interface: RS485
Input FunctionSwitch: 1 x dry contact
Colour CodeFront: dark grey RAL 7016
Display TypeBacklit LCD
Display Size56 x 25 mm
Function AvailableManual programming; Automatic initialisation; Automatic detection; Advanced programming (expert); Any step sequence
Metering TypePower factor and displacement PF (signed, four quadrant); Total current harmonic distortion THD (I); Power factor average over lifetime; Temperature maximum; Phase current I1, I2, I3 RMS on load; Active power P, P1, P2, P3 on load; Reactive power Q, Q1, Q2, Q3 on load; Apparent power S, S1, S2, S3 on load; Voltage U21, U32, U13, V1, V2, V3 on load
Type Of MeasurementCapacitor current overload Irms/I1; Individual voltage harmonic; Power factor; Operating time; Cos φ; Ambient temperature inside the cubicle; Tan φ
Information DisplayedNumber of switching cycles per step; Individual step size in kVAr; Remaining step capacity in %
Type Of AlarmsStep power loss (< 75 %) / Action: message and alarm contact + step blocked; Step faulty / Action: message and alarm contact + step blocked; High current (> 6 A CT) / Action: message and alarm contact; Hunting (unstable regulation) / Action: message and alarm contact + step blocked; Low current (< 15 mA CT) / Action: message and alarm contact; Overcompensation / Action: message and alarm contact;
Data Recording5 alarms
Operational Hours Alarm100000 h without maintenance
Operational Counter Alarm65000 cycles without maintenance
Input TypePhase to phase; Phase to neutral; Insensitive to CT polarity; Insensitive to phase rotation polarity; Current input CT...X/5 A and X/1 A
Output TypeControl relay: 0.2 A 110 V DC; Control relay: 1 A 48 V DC; Control relay: 2 A 400 V AC 50/60 Hz; Control relay: 1 A 24 V DC; Control relay: 5 A 250 V AC 50/60 Hz; Control relay: 5 A 120 V AC 50/60 Hz; Fan: 5 A 250 V AC 50/60 Hz; Fan: 1 A 48 V DC; Alarm relay: 5 A 250 V AC 50/60 Hz; Alarm relay: 1 A 48 V DC
Maximum At The Common Terminal10 A
Settings Operating ModeAutomatic; Manual
Type Of SettingChoice of stepping programs: auto; Choice of stepping programs: LIFO; Choice of stepping programs: linear; Delay between 2 successive switch on the same step: 5...1200 s; Step configuration programming: auto; Step configuration programming: off; Step configuration programming: fixed; Target cos phi: 0.7 inductive...0.7 capacitive; Target cos phi: dual cos φ
Measurement AccuracyVoltage +/- 1 %; Current +/- 1 %; Frequency +/- 1 %; Energy (P,Q,S) +/- 2 %; Cos φ +/- 2 %; Total voltage harmonic distortion THD (U) +/- 2 %; Individual voltage harmonic +/- 3 %; Temperature +/- 3 °C
Time Delay Range1...6500 s (on reconnection); 1...6500 s (on response)
Provided EquipmentUser manual
Mounting ModeFlush-mounted
Mounting SupportPanel - thickness: 1…3 mm
Mounting LocationIn cabinet
Cut-out Dimensions138 x 138 mm
Height144 mm
Width144 mm
Depth58 mm
Net Weight0.6 kg
Compatibility CodeVPL 12
Environment6
StandardsIEC 61000-6-4; UL 61010-1; EN 61010-1; IEC 61000-6-2; IEC 61326-1
Product CertificationsEAC; NRTL; cNRTL; CE
IP Degree Of ProtectionFront face: IP41; Rear face: IP20
Operating Altitude<= 2000 m
Ambient Air Temperature For Operation-20…60 °C
Ambient Air Temperature For Storage-40…85 °C
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height9.200 cm
Package 1 Width17.700 cm
Package 1 Length18.400 cm
Package 1 Weight727.000 g
Unit Type Of Package 2S03
Number Of Units In Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.155 kg
Unit Type Of Package 3P06
Number Of Units In Package 364
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight58.408 kg
Logistical informations1
Country Of OriginDE
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents3

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support