Schneider XALK1781H29 - EMERGENCY STOP CONT. BOX
Schneider

XALK1781H29 - EMERGENCY STOP CONT. BOX

Schneider XALK1781H29, EMERGENCY STOP CONT. BOX. Category: Harmony XALD, XALK. Request a quote for price and lead time.

Key Specifications

Range Of Product
Harmony XALK
Product Or Component Type
Complete control station
Device Short Name
XALK
Product Destination
For XB5 Ø 22 mm control and signalling units

Product Description

  • This control station with mushroom head push-button for emergency stop function is ideal for situations where quick actions are required for a process or machine to function correctly or where operator movements require maximum ergonomy
  • Its schematic is clearly distinguishable thanks to clear colors
  • It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments

Key Features

  • "Full compatibility with the Ø 22 mm plastic push buttons, switches and pilot lights of the Harmony XB5 range"
  • "Complete, ready-to-install stations with 1 to 3 buttons for the most common functions"
  • "Modular system and simple to cable universal range"
  • "Possibility to add up to 3 NO or NC contact blocks per operating head"
  • "Polycarbonate pre-drilled control stations"

Technical Specifications

Main14
Range Of ProductHarmony XALK
Product Or Component TypeComplete control station
Device Short NameXALK
Product DestinationFor XB5 Ø 22 mm control and signalling units
Control Station ApplicationEmergency stop function
Colour Of Base Of EnclosureLight grey (RAL 7035)
Colour Of CoverYellow (RAL 1021)
MaterialPolycarbonate
Operator Profile1 mushroom head push-button
Operators DescriptionRed ''EMERGENCY STOP'' 1 NC
ResetTurn to release
Control Station Composition1 mushroom head Ø 40 mm push-button, red 1 NC EMERGENCY STOP marking
Marking LocationMarking on legend holder
Contact OperationSlow-break
Complementary34
AC Control Voltage 50 HZ120…600 V
Cable Entry1 knock-out for cable entry 0…14 mm; 2 knock-outs for Pg 13 cable gland and ISO M20 0…12 mm
AC Control Voltage 60 HZ120…600 V
Net Weight0.194 kg
DC Control Voltage125…600 V
Resistance To High Pressure Washer7000000 Pa at 55 °C, distance : 0.1 m
Number Of Command Positions1
Number Of Indicator Lights0
Number Of Push Buttons0
Positive OpeningWith conforming to IEC 60947-5-1 appendix K
Operating Travel1.5 mm (NC changing electrical state); 4.3 mm (total travel)
Operating Force44 N
Number Of Selector Switches0
Mechanical Durability300000 cycles
Connections - TerminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1; Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1
Number Of Key Switches0
Tightening Torque0.8…1.2 N.m conforming to IEC 60947-1
Shape Of Screw HeadCross compatible with Philips no 1 screwdriver; Cross compatible with pozidriv No 1 screwdriver; Slotted compatible with flat Ø 4 mm screwdriver; Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts MaterialSilver alloy (Ag/Ni)
Short-circuit Protection10 A cartridge fuse type gG conforming to IEC 60947-5-1
[Ith] Conventional Free Air Thermal Current10 A conforming to IEC 60947-5-1
Number Of Mushroom-shaped Push-buttons1
[Ui] Rated Insulation Voltage600 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-1
[Ie] Rated Operational Current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1; 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1; 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1; 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
Electrical Durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.2 A at 110
Emergency Power OffNo
Electrical ReliabilityΛ < 10exp(-6) at 5 V, 1 mA conforming to IEC 60947-5-4; Λ < 10exp(-8) at 17 V, 5 mA conforming to IEC 60947-5-4
Number Of Contacts As Normally Closed Contact1
Number Of Contacts As Normally Open Contact0
Number Of Contacts As Change-over Contact0
Housing MaterialPlastic
Housing ColourYellow
Colour Of CoverYellow
Environment10
Protective TreatmentTH
Ambient Air Temperature For Storage-40…70 °C
Ambient Air Temperature For Operation-40…70 °C
Overvoltage CategoryClass II conforming to IEC 60536
IP Degree Of ProtectionIP66 conforming to IEC 60529; IP67; IP69; IP69K
NEMA Degree Of ProtectionNEMA 13; NEMA 4X
IK Degree Of ProtectionIK03 conforming to IEC 62262
StandardsIEC 60947-1; IEC 60947-5-4; CSA C22.2 No 14; IEC 60947-5-1; JIS C 4520; IEC 60204-1; UL 508; ISO 13850; IEC 60947-5-5
Vibration Resistance5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6
Shock Resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height7.0 cm
Package 1 Width7.0 cm
Package 1 Length10.0 cm
Package 1 Weight160.0 g
Unit Type Of Package 2S03
Number Of Units In Package 240
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight6.849 kg
Logistical informations1
Country Of OriginCZ
Contractual warranty1
Warranty (in Months)18

Documents and Downloads