XPSMCMC10804 - Safety PLC (Cat.4, Pl e, SIL3 Safety CPU), 8 safety inputs, 4 dual safety outputs, 24V DC
Schneider XPSMCMC10804, Safety PLC (Cat.4, Pl e, SIL3 Safety CPU), 8 safety inputs, 4 dual safety outputs, 24V DC. Category: Modicon MCM. Request a quote for price and lead time.
- Reference:XPSMCMC10804
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:1,157.00 EUR (Request a quote)
Key Specifications
- Range Of Product
- Modicon Safety automation
- Device Short Name
- XPSMCM
- Electrical Connection
- Screw terminal
- Product Or Component Type
- Safety controller CPU
Product Description
This Modicon MCM safety controller CPU is supplied with 24Vdc, has 8 safe digital inputs, 4 start/restart interlock inputs, 4 single channel OSSD, 4 test outputs, 4 configurable status outputs, fitted with captive screw clamp terminals. It embeds a Mini USB 2.0 connector to receive the configuration done with the software EcoStruxure Machine Expert - HVAC. It is an appropriate solution for machines with a small number of safety functions requiring the configuration flexibility of a safety controller. It can be used as standalone or with fourteen expansion modules. The system is expandable up to 128 inputs, 16 outputs and up to 32 diagnostic status outputs, ideal for machines requiring multiple safety function monitoring. This safety controller CPU figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, communication, master enable, restart signal, output channels). It is a CPU with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. It weighs 0.25kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safety controller CPU instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Key Features
- "Modular safety controller are designed to provide safety solutions requiring conformity to PLe and SIL3"
- "Reduce time-to-market: Offers designed specifically meeting the 6 safety functions required on your machine"
- "Modicon MCM offers an extensive range of safety products designed to provide protection for personnel and equipment"
- "Modicon MCM safety controller are designed for monitoring multiple safety functions"
- "Increase profitability: Safety designed from standalone components to embedded safety network solutions"
Technical Specifications
Main14
| Range Of Product | Modicon Safety automation |
|---|---|
| Device Short Name | XPSMCM |
| Electrical Connection | Screw terminal |
| Product Or Component Type | Safety controller CPU |
| [Us] Rated Supply Voltage | 24 V - 20...20 % DC |
| Number Of Inputs | 8 digital for input connection; 4 digital for interlock start/restart or external device monitoring |
| Number Of Outputs | 4 safety outputs OSSD for contactor/drive connection; 4 test for line control outputs; 4 configurable for diagnostic connection |
| Discrete Input Voltage | 24 V |
| Discrete Output Current | 400 mA |
| Discrete Input Current | 400 mA |
| Discrete Input Type | Safety input; PNP |
| Discrete Output Type | PNP |
| Function Of Module | Emergency stop conforming to ISO 13850; Guard monitoring conforming to EN/ISO 14119; Enabling switch monitoring conforming to IEC 60947-5-1; Light curtain monitoring conforming to IEC 61496-1; Foot switch monitoring conforming to IEC 60947-5-1; Light curtain monitoring conforming to EN/ISO 14119; Switch monitoring conforming to EN 574; Two-hand control conforming to EN/ISO 14119; Safety mat monito |
| Backplane Connector | Without |
Complementary17
| Synchronisation Time Between Inputs | < 0.5 ms |
|---|---|
| Power Dissipation In W | 3 W |
| Maximum Number Of I/O Expansion Module | 14 with 128 discrete output(s) for input; 14 with 32.0 discrete output(s) for output |
| Integrated Connection Type | Backplane expansion bus; USB 2.0 port |
| Data Storage Equipment | SD card (optional) |
| Inductive Load | 2.4 mH |
| Load Capacitance | 0.82 µF |
| Safety Level | Can reach category 4 conforming to ISO 13849-1; Can reach PL = e conforming to ISO 13849-1; Type 4 conforming to IEC 61496-1; SILCL 3 conforming to IEC 62061 |
| Quality Labels | CE |
| Local Signalling | 1 LED green with PWR marking for power ON; 1 LED green with RUN marking for RUN (status); 1 LED red with E IN marking for internal error; 1 LED red with E EX marking for external error; 1 LED orange with COM marking for communication; 1 LED blue with EN marking for master enable; 8 LEDs yellow with IN marking for input status; 2 LEDs green/red with OUT marking for output status; 2 LEDs yellow with |
| Connections - Terminals | 2 captive screw terminals, removable terminal block; 1 captive screw terminals, removable terminal block |
| Cable Cross Section | 0.2…1.5 mm² - 24 AWG...16 AWG flexible cablewithout cable end; 0.2…2.5 mm² - 24 AWG...14 AWG flexible cablewithout cable end; 0.25…1 mm² - 23 AWG...18 AWG flexible cablewith cable end, without bezel; 0.25…2.5 mm² - 23 AWG...14 AWG flexible cablewith cable end, with bezel; 0.25…1.5 mm² - 23 AWG...16 AWG flexible cablewith cable end, without bezel; 0.5…1.5 mm² - 20 AWG...16 AWG flexible cablewith ca |
| Mounting Support | Omega 35 mm DIN rail conforming to EN 50022 |
| Depth | 114.5 mm |
| Height | 99 mm |
| Width | 22.5 mm |
| Net Weight | 0.155 kg |
Environment15
| Standards | IEC 61496-1; ISO 13849-1; IEC 61508; IEC 61800-5-1; IEC 62061 |
|---|---|
| Product Certifications | TÜV; RCM; cULus |
| IP Degree Of Protection | IP20 |
| Ambient Air Temperature For Operation | -10…55 °C |
| Ambient Air Temperature For Storage | -20…85 °C |
| Relative Humidity | 10…95 % |
| Pollution Degree | 2 |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV conforming to IEC 61800-5-1 |
| Safety Reliability Data | PFHd = 1.35E-8 1/h high; DC > 99 %; MTTFd < 100 years |
| Insulation | 250 V AC between power supply and housing conforming to IEC 61800-5-1 |
| Overvoltage Category | II |
| Electromagnetic Compatibility | Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC |
| Vibration Resistance | +/-0.35 mm (f= 10…55 Hz) conforming to IEC 61496-1 |
| Shock Resistance | 10 gn (duration = 16 ms) for 1000 shocks on each axis conforming to IEC 61496-1 |
| Service Life | 20 year(s) |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 4.500 cm |
| Package 1 Width | 12.600 cm |
| Package 1 Length | 16.500 cm |
| Package 1 Weight | 262.000 g |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 26 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.891 kg |
Logistical informations1
| Country Of Origin | IT |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.