Schneider XPSMP11123 - module XPS-MP - 2 independent functions - 24 V DC
Schneider

module XPS-MP - 2 independent functions - 24 V DC

Not for sale

Schneider XPSMP11123, module XPS-MP - 2 independent functions - 24 V DC. Category: Modicon MCM. Not for sale; no price or quote is offered for this product.

Key Specifications

Range Of Product
Preventa Safety automation
Product Or Component Type
Safety controller with pre-defined function
Safety Module Name
XPSMP
Safety Module Application
2 independent functions

Product Description

This XPSMP safety contoller can handle 2 independent safety functions. This safety controller with pre-defined functions meets the requirements of PL e/Category 4 conforming EN ISO 13849-1 and SILCL 3 conforming to EN/IEC 61508 and EN/IEC 62061. It enables two independent safety functions (selected from a choice of 15 pre-defined configurations) to be performed using the same product. It complies with the most stringent functional safety requirements thanks to multiple configurable safety functions. It has additional solid-state output for communication with PLCs about safety status of your process.

Technical Specifications

Main12
Range Of ProductPreventa Safety automation
Product Or Component TypeSafety controller with pre-defined function
Safety Module NameXPSMP
Safety Module Application2 independent functions
Safety Use CategoryCategory 4 maximum conforming to EN/IEC 60954-1
Type Of StartAutomatic or unmonitored (configuration 1); Automatic or unmonitored (configuration 10); Automatic or unmonitored (configuration 11); Automatic or unmonitored (configuration 14); Automatic or unmonitored (configuration 3); Automatic or unmonitored (configuration 5); Automatic or unmonitored (configuration 7); Monitored (configuration 12); Monitored (configuration 13); Monitored (configuration 15);
ChecksConfiguration (configuration 10); Configuration (configuration 13); Configuration (configuration 3); Configuration (configuration 4); Configuration (configuration 5); Configuration (configuration 6); Configuration (configuration 9)
StandardsEN/IEC 60947-1 + A11; EN/IEC 60947-5-1; EN/IEC 60204-1; DIN V VDE 801 + A1
Product CertificationsUL; CSA; BIA
[Us] Rated Supply Voltage24 V DC - 20...20 %
Connections - TerminalsCaptive screw clamp terminals flexible cable: 0.14...0.75 mm² without cable end, 2 wires; Captive screw clamp terminals solid cable: 0.14...0.75 mm² without cable end, 2 wires; Captive screw clamp terminals flexible cable: 0.14...2.5 mm² without cable end, 1 wire; Captive screw clamp terminals solid cable: 0.14...2.5 mm² without cable end, 1 wire; Captive screw clamp terminals flexible cable: 0.25
Safety LevelCan reach PL e/category 4 conforming to EN/ISO 13849-1; Can reach SIL 3 conforming to EN/IEC 62061
Complementary23
Function Of ModuleConfiguration 0: functions disabled (factory setting); Configuration 1: emergency stop monitoring 1-channel wiring, category 2; Configuration 10: enabling grip switch monitoring (3-position switch), category 4; Configuration 11: sensing mat and edges monitoring, category 3; Configuration 12: sensing mat and edges monitoring, category 3; Configuration 13: relay output safety light curtain monitorin
Synchronisation Time Between Inputs0.5 s (configuration 13); 1.5 s (configuration 14); 1.5 s (configuration 15); 1.5 s (configuration 5); 1.5 s (configuration 6); 1.5 s (configuration 9); Unlimited (configuration 3); Unlimited (configuration 4); Unlimited (configuration 7); Unlimited (configuration 8)
Power Consumption In W5 W
Input Protection TypeInternal, electronic
[Uc] Control Circuit Voltage24 V
Maximum Line Resistance100 Ohm <2000 m
Number Of Safety Circuits3 NO relays per function (6 NO total), volt-free
Number Of Additional Circuits3 solid state outputs
Breaking Capacity180 VA holding AC-15 C300 relay output; 1800 VA inrush AC-15 C300 relay output
Output Thermal Current2 A for 1 output and 4 A for the other 2 outputs for relay; 3.3 A for all 3 outputs relay simultaneously; 6 A for 1 output and 2 A for the other 2 outputs for relay
[Ith] Conventional Free Air Thermal Current20 A
Associated Fuse Rating4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200; 6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum Output Current10 mA for relay output
Minimum Output Voltage17 V for relay output
Maximum Response Time On Input Open30 ms
[Ui] Rated Insulation Voltage300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
[Uimp] Rated Impulse Withstand Voltage4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
Local Signalling12 LEDs
Mounting Support35 mm symmetrical DIN rail
Depth114 mm
Height99 mm
Width45 mm
Net Weight0.32 kg
Environment3
IP Degree Of ProtectionIP20 (terminals); IP40 (enclosure)
Ambient Air Temperature For Operation-10…55 °C
Ambient Air Temperature For Storage-25…85 °C
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height6.5 cm
Package 1 Width12 cm
Package 1 Length16 cm
Package 1 Weight452 g
Unit Type Of Package 2S03
Number Of Units In Package 220
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight9.762 kg
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents3

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support