module XPS-MP - 2 independent functions - 24 V DC

Schneider XPSMP11123, module XPS-MP - 2 independent functions - 24 V DC. Category: Modicon MCM. Not for sale; no price or quote is offered for this product.
- Reference:XPSMP11123
- Manufacturer / Brand:Schneider
Key Specifications
- Range Of Product
- Preventa Safety automation
- Product Or Component Type
- Safety controller with pre-defined function
- Safety Module Name
- XPSMP
- Safety Module Application
- 2 independent functions
Product Description
This XPSMP safety contoller can handle 2 independent safety functions. This safety controller with pre-defined functions meets the requirements of PL e/Category 4 conforming EN ISO 13849-1 and SILCL 3 conforming to EN/IEC 61508 and EN/IEC 62061. It enables two independent safety functions (selected from a choice of 15 pre-defined configurations) to be performed using the same product. It complies with the most stringent functional safety requirements thanks to multiple configurable safety functions. It has additional solid-state output for communication with PLCs about safety status of your process.
Technical Specifications
Main12
| Range Of Product | Preventa Safety automation |
|---|---|
| Product Or Component Type | Safety controller with pre-defined function |
| Safety Module Name | XPSMP |
| Safety Module Application | 2 independent functions |
| Safety Use Category | Category 4 maximum conforming to EN/IEC 60954-1 |
| Type Of Start | Automatic or unmonitored (configuration 1); Automatic or unmonitored (configuration 10); Automatic or unmonitored (configuration 11); Automatic or unmonitored (configuration 14); Automatic or unmonitored (configuration 3); Automatic or unmonitored (configuration 5); Automatic or unmonitored (configuration 7); Monitored (configuration 12); Monitored (configuration 13); Monitored (configuration 15); |
| Checks | Configuration (configuration 10); Configuration (configuration 13); Configuration (configuration 3); Configuration (configuration 4); Configuration (configuration 5); Configuration (configuration 6); Configuration (configuration 9) |
| Standards | EN/IEC 60947-1 + A11; EN/IEC 60947-5-1; EN/IEC 60204-1; DIN V VDE 801 + A1 |
| Product Certifications | UL; CSA; BIA |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
| Connections - Terminals | Captive screw clamp terminals flexible cable: 0.14...0.75 mm² without cable end, 2 wires; Captive screw clamp terminals solid cable: 0.14...0.75 mm² without cable end, 2 wires; Captive screw clamp terminals flexible cable: 0.14...2.5 mm² without cable end, 1 wire; Captive screw clamp terminals solid cable: 0.14...2.5 mm² without cable end, 1 wire; Captive screw clamp terminals flexible cable: 0.25 |
| Safety Level | Can reach PL e/category 4 conforming to EN/ISO 13849-1; Can reach SIL 3 conforming to EN/IEC 62061 |
Complementary23
| Function Of Module | Configuration 0: functions disabled (factory setting); Configuration 1: emergency stop monitoring 1-channel wiring, category 2; Configuration 10: enabling grip switch monitoring (3-position switch), category 4; Configuration 11: sensing mat and edges monitoring, category 3; Configuration 12: sensing mat and edges monitoring, category 3; Configuration 13: relay output safety light curtain monitorin |
|---|---|
| Synchronisation Time Between Inputs | 0.5 s (configuration 13); 1.5 s (configuration 14); 1.5 s (configuration 15); 1.5 s (configuration 5); 1.5 s (configuration 6); 1.5 s (configuration 9); Unlimited (configuration 3); Unlimited (configuration 4); Unlimited (configuration 7); Unlimited (configuration 8) |
| Power Consumption In W | 5 W |
| Input Protection Type | Internal, electronic |
| [Uc] Control Circuit Voltage | 24 V |
| Maximum Line Resistance | 100 Ohm <2000 m |
| Number Of Safety Circuits | 3 NO relays per function (6 NO total), volt-free |
| Number Of Additional Circuits | 3 solid state outputs |
| Breaking Capacity | 180 VA holding AC-15 C300 relay output; 1800 VA inrush AC-15 C300 relay output |
| Output Thermal Current | 2 A for 1 output and 4 A for the other 2 outputs for relay; 3.3 A for all 3 outputs relay simultaneously; 6 A for 1 output and 2 A for the other 2 outputs for relay |
| [Ith] Conventional Free Air Thermal Current | 20 A |
| Associated Fuse Rating | 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200; 6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum Output Current | 10 mA for relay output |
| Minimum Output Voltage | 17 V for relay output |
| Maximum Response Time On Input Open | 30 ms |
| [Ui] Rated Insulation Voltage | 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| Local Signalling | 12 LEDs |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 114 mm |
| Height | 99 mm |
| Width | 45 mm |
| Net Weight | 0.32 kg |
Environment3
| IP Degree Of Protection | IP20 (terminals); IP40 (enclosure) |
|---|---|
| Ambient Air Temperature For Operation | -10…55 °C |
| Ambient Air Temperature For Storage | -25…85 °C |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 6.5 cm |
| Package 1 Width | 12 cm |
| Package 1 Length | 16 cm |
| Package 1 Weight | 452 g |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 20 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 9.762 kg |
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads